TAS5825M: DSP默认数值和手册描写不一致

Part Number:TAS5825M

左侧为PPC3上显示的默认值是0 dB,生成的配置文件,和右侧手册描写不一致。

想手动写入threshold来控制DRC,能否公开配置的实际值dB和写入DSP的值之间的计算。

Links:

您好,

已经收到了您的案例,调查需要些时间,感谢您的耐心等待。

 

TRANSLATE with x

English

Arabic
Hebrew
Polish

Bulgarian
Hindi
Portuguese

Catalan
Hmong Daw
Romanian

Chinese Simplified
Hungarian
Russian

Chinese Traditional
Indonesian
Slovak

Czech
Italian
Slovenian

Danish
Japanese
Spanish

Dutch
Klingon
Swedish

English
Korean
Thai

Estonian
Latvian
Turkish

Finnish
Lithuanian
Ukrainian

French
Malay
Urdu

German
Maltese
Vietnamese

Greek
Norwegian
Welsh

Haitian Creole
Persian

TRANSLATE with

COPY THE URL BELOW

Back

EMBED THE SNIPPET BELOW IN YOUR SITE

Enable collaborative features and customize widget: Bing Webmaster Portal
Back

,

Vivian Gao:

该值是PPC3用于DRC的默认值,在设备启动时写入。由于DRC被禁用,这对性能没有影响。计算结果在您显示的注册表映射中是公开的。数据以9.23数据格式存储,因此要计算I2C寄存器,您需要将十进制数据转换为9.23二进制数据。