tms320f28035HRPWM问题

最近在调hrpwm,问一下SFO_TI_BUild_v6.lib和SFO_TI_BUild_v6b.lib这两个库有什么区别?

Susan Yang:两者主要区别在于是否更新HRMSTEP

There are two different versions of the SFO library – SFO_TI_Build_V6.lib, and SFO_TI_Build_V6b.lib.

SFO_TI_Build_V6.lib does not update the HRMSTEP register with the value in MEP_ScaleFactor, while SFO_TI_Build_V6b.lib updates the register. Therefore, if using SFO_TI_Build_V6.lib and auto-conversion is enabled, the application should write MEP_Scalefactor in the HRMSTEP register as shown below.

最近在调hrpwm,问一下SFO_TI_BUild_v6.lib和SFO_TI_BUild_v6b.lib这两个库有什么区别?

naughty boy:

回复 Susan Yang:

那什么情况下用SFO_TI_BUild_v6.lib什么情况下用 SFO_TI_Build_V6b.lib?