新订购一台XDS200,资料太少,无法使用起来

XDS200, CCS5.3安装后,插上仿真器,设备管理器里只能找到两个串行端口,其中一上有问号。另一个正常。没有其他XDS200 仿真器设备。在 CCS5.3中配置好目标板,运行时显示-2083. 显示无法初始化仿真器。但在TI的网站和SD的网站上,都无法找到另外的关于XDS200的驱动。且因为较新,也没有更多的参考。现一直无法使用,请帮忙诊断。

Shine:

你的目标板是什么DSP? XDS200不支持一些老的DSP.http://processors.wiki.ti.com/index.php/Xds200#Q:_What_devices_are_supported_by_XDS2xx.3F

Shine:

回复 Shine:

另外, 你电脑的操作系统是Windows还是linux?

lslrf lslrf:

回复 Shine:

谢谢回复。我的操作系统是32位XP。目标芯片为28035或6446.。故障现象均一样。运行test connection时,显示如下信息。就和没接仿真器一样。我现在需要确定的是,CCS5.3是不是自带USB端的XDS200的驱动?安装后CCS5.3后,不需要再另外给XDS200安装驱动了吗?如果安装成功,设备管理器的名称叫什么?我现在中能找到两个串口。如附图

[Start]

Execute the command:

%ccs_base%/common/uscif/dbgjtag -f %boarddatafile% -r -o -S pathlength -S integrity

[Result]

E_RPCENV_IO_ERROR(-6) No connection: DTC_IO_Open::dtc_ioFailed to open i/o connection (xds2xxu:0)

An error occurred while soft opening the controller.

—–[An error has occurred and this utility has aborted]——————–

This error is generated by TI's USCIF driver or utilities.

The value is '-250' (0xffffff06).The title is 'SC_ERR_ECOM_EMUNAME'.

The explanation is:An attempt to access the named emulator via USCIF ECOM has failed.

[End]

Shine:

回复 lslrf lslrf:

ccs v5.3以上的版本自带xds200仿真器驱动, 不需要额外安装. 你的设备管理器名字是对的, 试试按照下面的步骤更新一下驱动, 目前最新的是5.0.899.0. 

Launch CCS, go into “help”->”Install New Software” menu. A new window “Install” will pop up.
Uncheck the “Group items by category”.
Click the “Add” button. A new window “Add repository” will pop up.
Name: enter “EMU SR (or something relevant to you)
Location: Copy the appropriate link (below) to the "Location" box Windows:http://software-dl.ti.com/dsps/dsps_public_sw/sdo_ccstudio/CCSv5.1/Updates/Emulation_SR/win32/full Click the “OK” button
Now check "TI Emulation" and "REQUIRED CCS Update Installation Tool".
Click on “Next” and follow steps like accepting license etc. It will mention that CCS will need to be restarted for items to install.
When CCS comes up, the Emulation installer exe will run. Follow the prompts to install in appropriate directory.
It will again ask to restart CCS. Choose to restart and you should have the updates fully installed. Accept any driver installation pop boxes you may see. 

lslrf lslrf:

回复 Shine:

已经安装到最新驱动了。经过确认,在WIN7 32位系统下都能正常并连接目标板正常工作。但所有的32位XP操作系统下,都有问题。问题都是在安装XDS2xx User CDC Serial Port 完成时系统提示该设备无法起动。然后设备管理器下面此设备前面就有了黄色叹号表示有问题。从而在CCS5.3中认为没有接入设备。  说明上有说可以支持XP的,是不是我的XP系统需要加什么补丁?

lslrf lslrf:

回复 lslrf lslrf:

无法解决吗?

Shine:

回复 lslrf lslrf:

我们的WinXP系统可以识别啊