我试了很久,还是没有通讯成功。我是按照cc1111的配置来设置的
Sverre:
Not clear from your post if you have the same sync word for both devices. CC1101 uses 0xD391 D391. Set up CC1310 with the same sync word.
CC1310, cc1101
Reply
380
Jose L.
Aug 19, 2016 1:17 PM
In reply to Sverre:
I setting up the cc1310 to 16bits Sync Word Length, and 0xD391 but not solve the problem. Attached configurations.
CC1310, cc1101
Reply
8035
PM
Aug 19, 2016 8:30 PM
In reply to Jose L.:
Hi,
Change Sync1 = 0xD3; Sync2 = 0x91 (Sync word = D391) ON CC1310. It seems you are using un Reverse.
Thanks,
PM
CC1310, cc1101
Reply
380
Jose L.
Aug 22, 2016 7:52 AM
In reply to PM:
Hi PM, I changed the Sync word but the modules do not communicate. Have you got any configuration for Smart RF Studio working that you can share?
CC1310, cc1101
Reply
116115
TER
Aug 22, 2016 2:04 PM
In reply to Jose L.:
E2E_ook_test.docx
I didn't see any issues
–PS. Thank you for clicking Verify Answer if this answered your question!
CC1310, cc1101
Reply
380
Jose L.
Aug 23, 2016 8:38 AM
In reply to TER:
Hi TER,i changed "whitening" from "cc1101/cc2500 compatible" to "no whitening" and now can communicate cc1101 with cc1310.