EVM430FR6047 HID Bridge Connected waiting for devices

Hi~I'm kk, I try to connect EVM430FR6047 to notebook and GUI shows "HID bridge connected—waiting for devices" . The hardware setting as attached photo- I also connecting the transducer on board and following the hardware guide, the water-mode GUI shows the same message as follow:

I don't know how to figure out the EVM430FR6047 connection issue,so please give me same suggestion.

Thank you very much~

Susan Yang:

请问您现在板子硬件是哪个版本呢?1.0还是2.0?您可以在板子上查看,如下图

1.0 的HW和GUI使用UART连接,而2.0使用的是I2C。这是需要调整跳线J5的

Susan Yang:

另外您买来之后有没有修改程序? 您可以在 www.ti.com/…/msp-ultrasonic-design-center 或者 http://software-dl.ti.com/msp430/msp430_public_sw/mcu/msp430/USSSWLib/latest/index_FDS.html 重新下载原始demo试试

kk Ting:

回复 Susan Yang:

謝謝回覆,看起來是沒寫版本~

kk Ting:

回复 Susan Yang:

有依照指示安裝程式~而且有換台電腦重新安裝,問題還是一樣。

kk Ting:

回复 kk Ting:

kk Ting:

原來的跳接如上圖,編號跟 2.5 Communications不一樣。若依照前述跳接一樣抓不到板子。

Susan Yang:

我看到您的板子和官网给出的 www.ti.com/…/EVM430-FR6047 是不一样的

看起来您现在使用的是MSP430FR6047 A版本的芯片,我会去向同事确认一下

另外您是否有按照

www.ti.com/…/slau720b.pdf

的2 Getting Started来操作?

芯片内的程序您是否重新烧录过?

kk Ting:

回复 Susan Yang:

1.我有按照 Getting Started来操作
2.這是前天新買的板子,我沒有做過任何處理,謝謝~

Susan Yang:

回复 kk Ting:

您的电源开关设置到ezFET位置了吗?

"HID Bridge connected — waiting for device" indicates that the HID bridge was able to connect to the MSP430FR6047, but that there is no serial response.

另外若是您修改过程序的话,请您重新刷一下程序试试

kk Ting:

回复 Susan Yang: