Part Number:TPL0102-100
Can I directly connect LA and WB of TPL0102 to achieve 0~200Ω resistance?
Currently, the software is unable to communicate with the module. After writing the device address, there is no ACK response.
Vivian Gao:
感谢您对TI产品的关注! 关于你的咨询,我们正在确认你的问题,稍后回复您。
,
tangjie tang:
Thank you and look forward to your reply.
,
tangjie tang:
Thank you and look forward to your reply.
,
Alice:
您好,
是的,可以将两个数字电位器通道串联,以增加端到端的电阻。
如果芯片没有ACK,请用示波器检查I2C时序。
,
tangjie tang:
The communication issue has been resolved. Regarding the control, I just need to control both the WA and WB registers simultaneously, right?
,
tangjie tang:
I set the values of both the WA and WB registers to 0. Theoretically, the resistance should be 0 ohms, but when we measured it with a multimeter, it was 19K ohms.Is there anything else that needs to be set up?
,
Alice:
您好,
tangjie tang 说:it was 19K ohms
理论上WA在LA位置(7.6.4 WRA),WB在LB位置(7.6.6 WRB),电阻为0.
实测每个通道的RWL是多少?您回读确认寄存器正确吗?
TPL0102 Two 256-Taps Digital Potentiometers With Non-Volatile Memory datasheet (Rev. C)
,
tangjie tang:
Thank you very much for your reply. All the issues have been resolved. It was caused by a problem with the IIC communication, where the WB register was written with abnormal data.
,
tangjie tang:
Thank you very much for your reply. All the issues have been resolved. It was caused by a problem with the IIC communication, where the WB register was written with abnormal data.
TI中文支持网