Part Number:CC2652P
CC2652P协调器,只有一个协调器的情况下运行48小时,调用ZCL发送出现ZBufferFull错误。调用nwkDB_CountTypes( NWK_DATABUF_SENT )检测发送状态,返回值等于NWK_MAX_DATABUFS_TOTAL值,该值设置为96。
然后统计ZMacDataReqSec调度次数,以及产生MAC_MCPS_DATA_CNF的次数,发现出现错误后,调度ZMacDataReqSec后没有产生MAC_MCPS_DATA_CNF。使用ZMacDataReqSec发送自定义的MAC数据包也抓不到数据。
但是调度一次ZMacScanReq,再调度ZMacDataReqSec,则可发出MAC数据包。而且连续发送多次ZMacDataReqSec自定义的数据包后,nwkDB_CountTypes( NWK_DATABUF_SENT )被清零,协调器又恢复畅通。
Links:
您好,
已经收到了您的案例,调查需要些时间,感谢您的耐心等待
TRANSLATE with x
English
Arabic
Hebrew
PolishBulgarian
Hindi
PortugueseCatalan
Hmong Daw
RomanianChinese Simplified
Hungarian
RussianChinese Traditional
Indonesian
SlovakCzech
Italian
SlovenianDanish
Japanese
SpanishDutch
Klingon
SwedishEnglish
Korean
ThaiEstonian
Latvian
TurkishFinnish
Lithuanian
UkrainianFrench
Malay
UrduGerman
Maltese
VietnameseGreek
Norwegian
WelshHaitian Creole
PersianTRANSLATE with
COPY THE URL BELOW
BackEMBED THE SNIPPET BELOW IN YOUR SITE
Enable collaborative features and customize widget: Bing Webmaster Portal
Back
,
Aries Lord:
我分别在SDK 7.10.02.23和SDK 7.40.00.17做过测试,均出现上述错误。
,
Daniel:
您好
这是对 Aries Lord 的重复支持请求、托比已经在调查:https://e2e.ti.com/f/1/t/1472317
TI中文支持网