LMX2572: 请教自动斜坡参数的设置

Part Number:LMX2572Other Parts Discussed in Thread:TICSPRO-SW,

鉴相频率Fpd=100Mhz

起始频率902.5MHz, 要求在890-915MHz之间往返扫频,步进50KHz,

测试了几天,输出依然不对,能否帮我检查一下,或者能给予一个寄存器数值表?

按照我的理解,

Fstep = 0.05*4=0.2; 
Fmax = 915*4=3660;Fmin = 890*4=3560;
Fstart = 3610;

RAMP_LIMIT_HIGH = pow(2,24)*(Fmax-Fstart)/100 = 8388608 = 0x00800000
RAMP_LIMIT_LOW = pow(2,33) – pow(2,24)*(Fstart-Fmin)/100 = 8581545984 = 0x1ff800000
RAMP0_INC = (fstep/100*pow(2,24)) = 33554 = 0x00008312
RAMP1_INC = pow(2,30) – RAMP0_INC = 1073708270 = 0x3FFF7CEE

其它相关的设置:

OUT_FORCE = 1;LD_DLY = 0;RAMP_MANUAL = 0;RAMP_TRIGA = 4;
RAMP_TRIGB = 4;
RAMP0_NEXT_TRIG = 0;
RAMP1_NEXT_TRIG = 0;
RAMP0_RST = 1;
RAMP1_RST = 1;
RAMP0_NEXT = 1;RAMP1_NEXT = 0;RAMP0_DLY = 0;RAMP1_DLY = 0;RAMP_TRIG_CAL = 1;
PLL_DEN = 0xFFFFFFFF;

FRANK1:

感谢您对TI产品的关注!关于你的咨询,我们正在确认你的问题,稍后回复您。

,

Lydia:

您好,

我建议使用 TICS Pro (www.ti.com/…/TICSPRO-SW))生成寄存器设置、这可以确保寄存器设置正确。

另请阅读 EVM 用户指南、了解如何设置斜坡。 https://www.ti2k.com/wp-content/uploads/ti2k/DeyiSupport_时钟和时序_snau217b.pdf

,

Zhengyu Xu:

谢谢关注,我试过TICS Pro了,反复测试解决不了才来这里咨询的。

,

Lydia:

您好,

您能否向我提供你的 TICS Pro 配置以供查看? 

,

Zhengyu Xu:

未果,换成ADF4158,功能顺利实现,LMX2572放弃。

,

Lydia:

好的,如果以后在使用TI器件过程中有问题,欢迎随时来咨询。