TMUX7219: when SEL was set,how large crush current could be from D to S?

Part Number:TMUX7219

As above, when "SEL" was set, "s2" was connected to "D". Capacitor "C1" was charged from source "V2". At the beginning of charging, the cursh current would be very large. Would the device be damaged at this situation? 

Amy Luo:

您好,

datasheet 给出了其不同封装、不同电压、不同环境温度下的连续电流,如下截图:

浪涌电流的话,我认为应该由其发热功率确定,看下下面FAQ是否对您有帮助:

https://e2e.ti.com/support/switches-multiplexers-group/switches-multiplexers/f/switches-multiplexers-forum/1063078/faq-how-to-calculate-the-max-junction-temperature-of-an-analog-switch-multiplexer

[FAQ] More Frequently Asked Questions about signal switches and multiplexers  这里有一个计算EXCEL表格

[FAQ] Frequently Asked Questions – Switches & Multiplexers Forum

,

JNYU CHEN:

链接及表格都是计算长时间的平均功率引起的温升,跟我所说的浪涌电流还是有点区别。

对比MOSFET,可以参考手册提供的最大单脉冲电流和最大重复脉冲电流,使用该脉冲电流计算平均功耗,一般是小于额定功耗的,但是仍然限制了最大电流。其原因可能是由于热阻的存在,脉冲电流引起的结温升无法快速散热,此时仍然处于非热平衡状态;而使用平均功率计算温升时,结温和外壳已经达到热平衡了。

最好是能够提供最大单脉冲电流和最大重复脉冲电流参数,或者是类似SOA曲线,这样也方便参考计算。

,

Amy Luo:

很抱歉,TI没有提供最大脉冲电流参数,在您的应用中需要的最大脉冲电流是多少?如果需要的电流比较大的话,没准您需要的是 负载开关( load switch)或高侧开关(high-side switch),具体您可以在“电源管理”版块咨询,因为 负载开关和高侧开关属于电源产品,电源工程师会为您提供更好的支持。