PGA900: OWI ,reset

Part Number:PGA900

Hello,

I had some problem about OWI with PGA900, when I add the active plus , 7.3V-5.6V-7.3V, the waveform like below, IT can't activate the IC ,and  always happened the strange status, the PGA900 IC seemed reset..see the second picture.it shows the error-615 and error-2064, also :unable to determine target status after 20 attempts, failed to remove the debug status from the target before disconnecting.

I want to know which reason can cause this problem ..what can cause the IC reset.

  

thanks and best regards

Kim ma

Amy Luo:

Hi Kim,

PGA900 is a product with limited information. This product is supported by the team of engineers in the US. I will forward your questions to them through the intranet. After receiving their reply, I will reply to you by email.

Best Regards,

Amy

,

jinyan ma:

Hi Amy:

thanks for your reply and your  effort. I'm waiting for your good news.

best regards

Kim

,

Amy Luo:

Our E2E English forum engineer see that you have posted your questions here:  https://e2e.ti.com/support/sensors-group/sensors/f/sensors-forum/1082470/pga900-pga900-bga-type-owi-issue

He told me that he has replied to your post and has set up some offline email communications to discuss this issue.

,

jinyan ma:

Hi Amy:

yes ! thanks a lot .now I know the reason.  the slew rate on VDD should below 0.5V/us

best regards!

Kim

,

Amy Luo:

Hi Kim,

I'm glad you found the reason. Thank you for your feedback.

Best Regards,

Amy