TI中文支持网
TI专业的中文技术问题搜集分享网站

BQ4050 三元锂电芯电压达到3.9V但是SOC为0%

Other Parts Discussed in Thread:BQ4050

我们有一个用BQ4050的产品,在客户测试,发现SOC为0%但是电压已经达到3.9V,暂时还没有数据反馈。

我们推测会不会是充电电流没有达到阈值,导致SOC没有计算?这个想请问一下BQ4050是否有这种机制,或者说有没有类似案例是什么原因造成的? 还望大家帮忙解答一下,谢谢。

Star Xu:

您好,建议问一下客户做了哪些测试,是否有reset,reset以后SOC会不准确

,

Gary Liu4:

* Texas Instruments Data Flash File

* File created Tue Feb 23 09:52:10 2021

*

* Device Number 9E34

* Firmware Version 0.01

* Build Number 22

* Order Number 0

*

* bqz Device Number 9e34

* bqz Firmware Version 0.01

* bqz Build Number 22

*

* Field Order: Class name
 Subclass name
 Parameter name
 Parameter Value
 Display Units

Calibration
Voltage
Cell Gain
12178

Calibration
Voltage
Pack Gain
49499

Calibration
Voltage
BAT Gain
49293

Calibration
Current
CC Gain
3.183
mOhm

Calibration
Current
Capacity Gain
3.183
mOhm

Calibration
Current Offset
CC Offset
0

Calibration
Current Offset
Coulomb Counter Offset Samples
64

Calibration
Current Offset
Board Offset
0

Calibration
Current Offset
CC Auto Config
7
hex

Calibration
Current Offset
CC Auto Offset
-36

Calibration
Temperature
Internal Temp Offset
2.6
°C

Calibration
Temperature
External1 Temp Offset
0.3
°C

Calibration
Temperature
External2 Temp Offset
-0.6
°C

Calibration
Temperature
External3 Temp Offset
-0.8
°C

Calibration
Temperature
External4 Temp Offset
-1.2
°C

Calibration
Internal Temp Model
Int Gain
-12143

Calibration
Internal Temp Model
Int base offset
6232

Calibration
Internal Temp Model
Int Minimum AD
0

Calibration
Internal Temp Model
Int Maximum Temp
6232
0.1degK

Calibration
Cell Temperature Model
Coeff a1
-11130

Calibration
Cell Temperature Model
Coeff a2
19142

Calibration
Cell Temperature Model
Coeff a3
-19262

Calibration
Cell Temperature Model
Coeff a4
28203

Calibration
Cell Temperature Model
Coeff a5
892

Calibration
Cell Temperature Model
Coeff b1
328

Calibration
Cell Temperature Model
Coeff b2
-605

Calibration
Cell Temperature Model
Coeff b3
-2443

Calibration
Cell Temperature Model
Coeff b4
4696

Calibration
Cell Temperature Model
Rc0
11703

Calibration
Cell Temperature Model
Adc0
11703

Calibration
Cell Temperature Model
Rpad
0

Calibration
Cell Temperature Model
Rint
0

Calibration
Fet Temperature Model
Coeff a1
-11130

Calibration
Fet Temperature Model
Coeff a2
19142

Calibration
Fet Temperature Model
Coeff a3
-19262

Calibration
Fet Temperature Model
Coeff a4
28203

Calibration
Fet Temperature Model
Coeff a5
892

Calibration
Fet Temperature Model
Coeff b1
328

Calibration
Fet Temperature Model
Coeff b2
-605

Calibration
Fet Temperature Model
Coeff b3
-2443

Calibration
Fet Temperature Model
Coeff b4
4696

Calibration
Fet Temperature Model
Rc0
11703

Calibration
Fet Temperature Model
Adc0
11703

Calibration
Fet Temperature Model
Rpad
0

Calibration
Fet Temperature Model
Rint
0

Calibration
Current Deadband
Deadband
3
mA

Calibration
Current Deadband
Coulomb Counter Deadband
9
116nV

Settings
Protection
Protection Configuration
0
hex

Settings
Protection
Enabled Protections A
7f
hex

Settings
Protection
Enabled Protections B
5
hex

Settings
Protection
Enabled Protections C
0
hex

Settings
Protection
Enabled Protections D
0
hex

Settings
Permanent Failure
Enabled PF A
0
hex

Settings
Permanent Failure
Enabled PF B
0
hex

Settings
Permanent Failure
Enabled PF C
0
hex

Settings
Permanent Failure
Enabled PF D
0
hex

Settings
Configuration
Charging Configuration
0
hex

Settings
Configuration
Temperature Enable
1e
hex

Settings
Configuration
Temperature Mode
0
hex

Settings
Configuration
DA Configuration
1f
hex

Settings
Configuration
FET Options
41
hex

Settings
Configuration
Sbs Gauging Configuration
5
hex

Settings
Configuration
Sbs Configuration
20
hex

Settings
Configuration
Power Config
0
hex

Settings
Configuration
IO Config
0
hex

Settings
Configuration
LED Configuration
00d7
hex

Settings
Configuration
SOC Flag Config A
0c8c
hex

Settings
Configuration
SOC Flag Config B
8c
hex

Settings
Configuration
Balancing Configuration
1
hex

Settings
Configuration
CEDV Gauging Configuration
048a
hex

Settings
Configuration
CEDV Smoothing Config
0
hex

Settings
AFE
AFE Protection Control
73
hex

Settings
AFE
ZVCHG Exit Threshold
2200
mV

Settings
Fuse
PF Fuse A
0
hex

Settings
Fuse
PF Fuse B
0
hex

Settings
Fuse
PF Fuse C
0
hex

Settings
Fuse
PF Fuse D
0
hex

Settings
Fuse
Min Blow Fuse Voltage
3500
mV

Settings
Fuse
Fuse Blow Timeout
30
s

Settings
BTP
Init Discharge Set
800
mAh

Settings
BTP
Init Charge Set
800
mAh

Settings
SMBus
Address
16

Settings
SMBus
Address Check
ea

Settings
Manufacturing
Mfg Status init
02b0
hex

Protections
CUV
Threshold
2500
mV

Protections
CUV
Delay
2
s

Protections
CUV
Recovery
3000
mV

Protections
COV
Threshold Low Temp
4300
mV

Protections
COV
Threshold Standard Temp
4300
mV

Protections
COV
Threshold High Temp
4300
mV

Protections
COV
Threshold Rec Temp
4300
mV

Protections
COV
Delay
2
s

Protections
COV
Recovery Low Temp
4000
mV

Protections
COV
Recovery Standard Temp
4000
mV

Protections
COV
Recovery High Temp
4000
mV

Protections
COV
Recovery Rec Temp
4000
mV

Protections
OCC1
Threshold
5000
mA

Protections
OCC1
Delay
10
s

Protections
OCC2
Threshold
6000
mA

Protections
OCC2
Delay
6
s

Protections
OCC
Recovery Threshold
0
mA

Protections
OCC
Recovery Delay
5
s

Protections
OCD1
Threshold
-18750
mA

Protections
OCD1
Delay
10
s

Protections
OCD2
Threshold
-22500
mA

Protections
OCD2
Delay
6
s

Protections
OCD
Recovery Threshold
0
mA

Protections
OCD
Recovery Delay
5
s

Protections
AOLD
Latch Limit
0

Protections
AOLD
Counter Dec Delay
10
s

Protections
AOLD
Recovery
5
s

Protections
AOLD
Reset
15
s

Protections
AOLD
Threshold
ff
hex

Protections
ASCC
Latch Limit
0

Protections
ASCC
Counter Dec Delay
10
s

Protections
ASCC
Recovery
5
s

Protections
ASCC
Reset
15
s

Protections
ASCC
Threshold
77
hex

Protections
ASCD
Latch Limit
0

Protections
ASCD
Counter Dec Delay
10
s

Protections
ASCD
Recovery
5
s

Protections
ASCD
Reset
15
s

Protections
ASCD
Threshold 1
77
hex

Protections
ASCD
Threshold 2
e7
hex

Protections
OTC
Threshold
45
1°C

Protections
OTC
Delay
2
s

Protections
OTC
Recovery
40
1°C

Protections
OTD
Threshold
65
1°C

Protections
OTD
Delay
2
s

Protections
OTD
Recovery
60
1°C

Protections
OTF
Threshold
90
1°C

Protections
OTF
Delay
2
s

Protections
OTF
Recovery
80
1°C

Protections
UTC
Threshold
0
1°C

Protections
UTC
Delay
2
s

Protections
UTC
Recovery
5
1°C

Protections
UTD
Threshold
-20
1°C

Protections
UTD
Delay
2
s

Protections
UTD
Recovery
-15
1°C

Protections
HWD
Delay
10
s

Protections
PTO
Charge Threshold
2000
mA

Protections
PTO
Suspend Threshold
1800
mA

Protections
PTO
Delay
1800
s

Protections
PTO
Reset
2
mAh

Protections
CTO
Charge Threshold
2500
mA

Protections
CTO
Suspend Threshold
2000
mA

Protections
CTO
Delay
54000
s

Protections
CTO
Reset
2
mAh

Protections
OC
Threshold
300
mAh

Protections
OC
Recovery
2
mAh

Protections
OC
RSOC Recovery
90
%

Protections
CHGV
Threshold
500
mV

Protections
CHGV
Delay
30
s

Protections
CHGV
Recovery
-500
mV

Protections
CHGC
Threshold
500
mA

Protections
CHGC
Delay
2
s

Protections
CHGC
Recovery Threshold
100
mA

Protections
CHGC
Recovery Delay
2
s

Protections
PCHGC
Threshold
50
mA

Protections
PCHGC
Delay
2
s

Protections
PCHGC
Recovery Threshold
10
mA

Protections
PCHGC
Recovery Delay
2
s

Permanent Fail
SUV
Threshold
2200
mV

Permanent Fail
SUV
Delay
5
s

Permanent Fail
SOV
Threshold
4500
mV

Permanent Fail
SOV
Delay
5
s

Permanent Fail
SOCC
Threshold
10000
mA

Permanent Fail
SOCC
Delay
5
s

Permanent Fail
SOCD
Threshold
-10000
mA

Permanent Fail
SOCD
Delay
5
s

Permanent Fail
SOT
Threshold
65
1°C

Permanent Fail
SOT
Delay
5
s

Permanent Fail
SOTF
Threshold
100
1°C

Permanent Fail
SOTF
Delay
5
s

Permanent Fail
Open Thermistor
Threshold
-50
1°C

Permanent Fail
Open Thermistor
Delay
5
s

Permanent Fail
Open Thermistor
Fet Delta
20
1°C

Permanent Fail
Open Thermistor
Cell Delta
20
1°C

Permanent Fail
VIMR
Check Voltage
3500
mV

Permanent Fail
VIMR
Check Current
10
mA

Permanent Fail
VIMR
Delta Threshold
500
mV

Permanent Fail
VIMR
Delta Delay
5
s

Permanent Fail
VIMR
Duration
100
s

Permanent Fail
VIMA
Check Voltage
3700
mV

Permanent Fail
VIMA
Check Current
50
mA

Permanent Fail
VIMA
Delta Threshold
200
mV

Permanent Fail
VIMA
Delay
2
s

Permanent Fail
CFET
OFF Threshold
5
mA

Permanent Fail
CFET
OFF Delay
5
s

Permanent Fail
DFET
OFF Threshold
-5
mA

Permanent Fail
DFET
OFF Delay
5
s

Permanent Fail
FUSE
Threshold
5
mA

Permanent Fail
FUSE
Delay
5
s

Permanent Fail
AFER
Threshold
100

Permanent Fail
AFER
Delay Period
2
s

Permanent Fail
AFER
Compare Period
5
s

Permanent Fail
AFEC
Threshold
100

Permanent Fail
AFEC
Delay Period
5
s

Permanent Fail
2LVL
Delay
5
s

Permanent Fail
OPNCELL
Threshold
5000
mV

Permanent Fail
OPNCELL
Delay
5
s

Advanced Charge Algorithm
Temperature Ranges
T1 Temp
0
°C

Advanced Charge Algorithm
Temperature Ranges
T2 Temp
12
°C

Advanced Charge Algorithm
Temperature Ranges
T5 Temp
20
°C

Advanced Charge Algorithm
Temperature Ranges
T6 Temp
25
°C

Advanced Charge Algorithm
Temperature Ranges
T3 Temp
30
°C

Advanced Charge Algorithm
Temperature Ranges
T4 Temp
55
°C

Advanced Charge Algorithm
Temperature Ranges
Hysteresis Temp
1
°C

Advanced Charge Algorithm
Low Temp Charging
Voltage
4200
mV

Advanced Charge Algorithm
Low Temp Charging
Current Low
132
mA

Advanced Charge Algorithm
Low Temp Charging
Current Med
352
mA

Advanced Charge Algorithm
Low Temp Charging
Current High
264
mA

Advanced Charge Algorithm
Standard Temp Charging
Voltage
4200
mV

Advanced Charge Algorithm
Standard Temp Charging
Current Low
1980
mA

Advanced Charge Algorithm
Standard Temp Charging
Current Med
4004
mA

Advanced Charge Algorithm
Standard Temp Charging
Current High
2992
mA

Advanced Charge Algorithm
High Temp Charging
Voltage
4200
mV

Advanced Charge Algorithm
High Temp Charging
Current Low
1012
mA

Advanced Charge Algorithm
High Temp Charging
Current Med
1980
mA

Advanced Charge Algorithm
High Temp Charging
Current High
1496
mA

Advanced Charge Algorithm
Rec Temp Charging
Voltage
4200
mV

Advanced Charge Algorithm
Rec Temp Charging
Current Low
2508
mA

Advanced Charge Algorithm
Rec Temp Charging
Current Med
4488
mA

Advanced Charge Algorithm
Rec Temp Charging
Current High
3520
mA

Advanced Charge Algorithm
Pre-Charging
Current
88
mA

Advanced Charge Algorithm
Maintenance Charging
Current
44
mA

Advanced Charge Algorithm
Voltage Range
Precharge Start Voltage
2500
mV

Advanced Charge Algorithm
Voltage Range
Charging Voltage Low
2900
mV

Advanced Charge Algorithm
Voltage Range
Charging Voltage Med
3600
mV

Advanced Charge Algorithm
Voltage Range
Charging Voltage High
4000
mV

Advanced Charge Algorithm
Voltage Range
Charging Voltage Hysteresis
0
mV

Advanced Charge Algorithm
SoC Range
Charging SoC Med
50
%

Advanced Charge Algorithm
SoC Range
Charging SoC High
75
%

Advanced Charge Algorithm
SoC Range
Charging SoC Hysteresis
1
%

Advanced Charge Algorithm
Termination Config
Charge Term Taper Current
400
mA

Advanced Charge Algorithm
Termination Config
Charge Term Voltage
150
mV

Advanced Charge Algorithm
Charging Rate of Change
Current Rate
1
steps

Advanced Charge Algorithm
Charging Rate of Change
Voltage Rate
1
steps

Advanced Charge Algorithm
Charge Loss Compensation
CCC Current Threshold
3520
mA

Advanced Charge Algorithm
Charge Loss Compensation
CCC Voltage Threshold
4200
mV

Advanced Charge Algorithm
Cell Balancing Config
Cell Balance Threshold
3100
mV

Advanced Charge Algorithm
Cell Balancing Config
Cell Balance Window
10
mV

Advanced Charge Algorithm
Cell Balancing Config
Cell Balance Min
5
mV

Advanced Charge Algorithm
Cell Balancing Config
Cell Balance Interval
3
s

Gas Gauging
Current Thresholds
Dsg Current Threshold
100
mA

Gas Gauging
Current Thresholds
Chg Current Threshold
50
mA

Gas Gauging
Current Thresholds
Quit Current
10
mA

Gas Gauging
Current Thresholds
Dsg Relax Time
10
s

Gas Gauging
Current Thresholds
Chg Relax Time
10
s

Gas Gauging
Design
Design Capacity mAh
7975
mAh

Gas Gauging
Design
Design Capacity cWh
11484
cWh

Gas Gauging
Design
Design Voltage
14400
mV

Gas Gauging
Cycle
Cycle Count Percentage
80
%

Gas Gauging
FD
Set Voltage Threshold
3000
mV

Gas Gauging
FD
Clear Voltage Threshold
3100
mV

Gas Gauging
FD
Set % RSOC Threshold
0
%

Gas Gauging
FD
Clear % RSOC Threshold
5
%

Gas Gauging
FC
Set Voltage Threshold
4200
mV

Gas Gauging
FC
Clear Voltage Threshold
4100
mV

Gas Gauging
FC
Set % RSOC Threshold
100
%

Gas Gauging
FC
Clear % RSOC Threshold
95
%

Gas Gauging
TD
Set Voltage Threshold
3200
mV

Gas Gauging
TD
Clear Voltage Threshold
3300
mV

Gas Gauging
TD
Set % RSOC Threshold
6
%

Gas Gauging
TD
Clear % RSOC Threshold
8
%

Gas Gauging
TC
Set Voltage Threshold
4200
mV

Gas Gauging
TC
Clear Voltage Threshold
4100
mV

Gas Gauging
TC
Set % RSOC Threshold
100
%

Gas Gauging
TC
Clear % RSOC Threshold
95
%

Gas Gauging
State
Cycle Count
1

Gas Gauging
State
Learned Full Charge Capacity
7290
mAh

Gas Gauging
CEDV cfg
EMF
3893

Gas Gauging
CEDV cfg
C0
760

Gas Gauging
CEDV cfg
R0
500

Gas Gauging
CEDV cfg
T0
4063

Gas Gauging
CEDV cfg
R1
1

Gas Gauging
CEDV cfg
TC
9

Gas Gauging
CEDV cfg
C1
0

Gas Gauging
CEDV cfg
Age Factor
0

Gas Gauging
CEDV cfg
Fixed EDV 0
2850

Gas Gauging
CEDV cfg
EDV 0 Hold Time
15
s

Gas Gauging
CEDV cfg
Fixed EDV 1
3385

Gas Gauging
CEDV cfg
EDV 1 Hold Time
3
s

Gas Gauging
CEDV cfg
Fixed EDV 2
3400

Gas Gauging
CEDV cfg
EDV 2 Hold Time
3
s

Gas Gauging
CEDV cfg
Battery Low %
12
%

Gas Gauging
CEDV cfg
Min Delta V Filter
500
mV

Gas Gauging
CEDV cfg
Learning Low Temp
119
0.1°C

Gas Gauging
CEDV cfg
OverLoad Current
10000
mA

Gas Gauging
CEDV cfg
Self Discharge Rate
20
0.01%/day

Gas Gauging
CEDV cfg
Electronics Load
0
3uA

Gas Gauging
CEDV cfg
Near Full
400
mAh

Gas Gauging
CEDV cfg
Reserve Capacity
0
mAh

Gas Gauging
CEDV cfg
Chg Eff
100
%

Gas Gauging
CEDV cfg
Dsg Eff
100
%

Gas Gauging
CEDV Profile 1
Voltage 0% DOD
4152
mV

Gas Gauging
CEDV Profile 1
Voltage 10% DOD
4050
mV

Gas Gauging
CEDV Profile 1
Voltage 20% DOD
3955
mV

Gas Gauging
CEDV Profile 1
Voltage 30% DOD
3856
mV

Gas Gauging
CEDV Profile 1
Voltage 40% DOD
3754
mV

Gas Gauging
CEDV Profile 1
Voltage 50% DOD
3655
mV

Gas Gauging
CEDV Profile 1
Voltage 60% DOD
3592
mV

Gas Gauging
CEDV Profile 1
Voltage 70% DOD
3540
mV

Gas Gauging
CEDV Profile 1
Voltage 80% DOD
3461
mV

Gas Gauging
CEDV Profile 1
Voltage 90% DOD
3349
mV

Gas Gauging
CEDV Profile 1
Voltage 100% DOD
2853
mV

Gas Gauging
CEDV Smoothing Config
Smoothing Start Voltage
3500
mV

Gas Gauging
CEDV Smoothing Config
Smoothing Delta Voltage
200
mV

Gas Gauging
CEDV Smoothing Config
Max Smoothing Current
8000
mA

Gas Gauging
CEDV Smoothing Config
EOC Smooth Current
0.2
%

Gas Gauging
CEDV Smoothing Config
EOC Smooth Current Time
60
s

Power
Power
Valid Update Voltage
3500
mV

Power
Shutdown
Shutdown Voltage
2200
mV

Power
Shutdown
Shutdown Time
10
s

Power
Shutdown
PF Shutdown Voltage
1750
mV

Power
Shutdown
PF Shutdown Time
10
s

Power
Shutdown
Charger Present Threshold
3000
mV

Power
Sleep
Sleep Current
5
mA

Power
Sleep
Bus Timeout
5
s

Power
Sleep
Voltage Time
5
s

Power
Sleep
Current Time
20
s

Power
Sleep
Wake Comparator
0
hex

Power
Ship
FET Off Time
10
s

Power
Ship
Delay
20
s

Power
Ship
Auto Ship Time
1440
min

Power
Power Off
Timeout
30
min

Power
Manual FET Control
MFC Delay
60
s

PF Status
Device Status Data
Safety Alert A
0
hex

PF Status
Device Status Data
Safety Status A
0
hex

PF Status
Device Status Data
Safety Alert B
0
hex

PF Status
Device Status Data
Safety Status B
0
hex

PF Status
Device Status Data
Safety Alert C
0
hex

PF Status
Device Status Data
Safety Status C
0
hex

PF Status
Device Status Data
Safety Alert D
0
hex

PF Status
Device Status Data
Safety Status D
0
hex

PF Status
Device Status Data
PF Alert A
0
hex

PF Status
Device Status Data
PF Status A
0
hex

PF Status
Device Status Data
PF Alert B
0
hex

PF Status
Device Status Data
PF Status B
0
hex

PF Status
Device Status Data
PF Alert C
0
hex

PF Status
Device Status Data
PF Status C
0
hex

PF Status
Device Status Data
PF Alert D
0
hex

PF Status
Device Status Data
PF Status D
0
hex

PF Status
Device Status Data
Fuse Flag
0
hex

PF Status
Device Status Data
Operation Status A
0
hex

PF Status
Device Status Data
Operation Status B
0
hex

PF Status
Device Status Data
Temp Range
0
hex

PF Status
Device Status Data
Charging Status A
0
hex

PF Status
Device Status Data
Charging Status B
0
hex

PF Status
Device Status Data
Gauging Status
0
hex

PF Status
Device Status Data
CEDV Status
0
hex

PF Status
Device Voltage Data
Cell 1 Voltage
0
mV

PF Status
Device Voltage Data
Cell 2 Voltage
0
mV

PF Status
Device Voltage Data
Cell 3 Voltage
0
mV

PF Status
Device Voltage Data
Cell 4 Voltage
0
mV

PF Status
Device Voltage Data
Battery Direct Voltage
0
mV

PF Status
Device Voltage Data
Pack Voltage
0
mV

PF Status
Device Current Data
Current
0
mA

PF Status
Device Temperature Data
Internal Temperature
-273.2
°C

PF Status
Device Temperature Data
External 1 Temperature
-273.2
°C

PF Status
Device Temperature Data
External 2 Temperature
-273.2
°C

PF Status
Device Temperature Data
External 3 Temperature
-273.2
°C

PF Status
Device Temperature Data
External 4 Temperature
-273.2
°C

PF Status
AFE Regs
AFE Interrupt Status
0
hex

PF Status
AFE Regs
AFE FET Status
0
hex

PF Status
AFE Regs
AFE RXIN
0
hex

PF Status
AFE Regs
AFE Latch Status
0
hex

PF Status
AFE Regs
AFE Interrupt Enable
0
hex

PF Status
AFE Regs
AFE FET Control
0
hex

PF Status
AFE Regs
AFE RXIEN
0
hex

PF Status
AFE Regs
AFE RLOUT
0
hex

PF Status
AFE Regs
AFE RHOUT
0
hex

PF Status
AFE Regs
AFE RHINT
0
hex

PF Status
AFE Regs
AFE Cell Balance
0
hex

PF Status
AFE Regs
AFE AD/CC Control
0
hex

PF Status
AFE Regs
AFE ADC Mux
0
hex

PF Status
AFE Regs
AFE LED Output
0
hex

PF Status
AFE Regs
AFE State Control
0
hex

PF Status
AFE Regs
AFE LED/Wake Control
0
hex

PF Status
AFE Regs
AFE Protection Control
0
hex

PF Status
AFE Regs
AFE OCD
0
hex

PF Status
AFE Regs
AFE SCC
0
hex

PF Status
AFE Regs
AFE SCD1
0
hex

PF Status
AFE Regs
AFE SCD2
0
hex

System Data
Manufacturer Data
Manufacturer Info A Length
32

System Data
Manufacturer Data
Manufacturer Info Block A01
61
Hex

System Data
Manufacturer Data
Manufacturer Info Block A02
62
Hex

System Data
Manufacturer Data
Manufacturer Info Block A03
63
Hex

System Data
Manufacturer Data
Manufacturer Info Block A04
64
Hex

System Data
Manufacturer Data
Manufacturer Info Block A05
65
Hex

System Data
Manufacturer Data
Manufacturer Info Block A06
66
Hex

System Data
Manufacturer Data
Manufacturer Info Block A07
67
Hex

System Data
Manufacturer Data
Manufacturer Info Block A08
68
Hex

System Data
Manufacturer Data
Manufacturer Info Block A09
69
Hex

System Data
Manufacturer Data
Manufacturer Info Block A10
6a
Hex

System Data
Manufacturer Data
Manufacturer Info Block A11
6b
Hex

System Data
Manufacturer Data
Manufacturer Info Block A12
6c
Hex

System Data
Manufacturer Data
Manufacturer Info Block A13
6d
Hex

System Data
Manufacturer Data
Manufacturer Info Block A14
6e
Hex

System Data
Manufacturer Data
Manufacturer Info Block A15
6f
Hex

System Data
Manufacturer Data
Manufacturer Info Block A16
70
Hex

System Data
Manufacturer Data
Manufacturer Info Block A17
71
Hex

System Data
Manufacturer Data
Manufacturer Info Block A18
72
Hex

System Data
Manufacturer Data
Manufacturer Info Block A19
73
Hex

System Data
Manufacturer Data
Manufacturer Info Block A20
74
Hex

System Data
Manufacturer Data
Manufacturer Info Block A21
75
Hex

System Data
Manufacturer Data
Manufacturer Info Block A22
76
Hex

System Data
Manufacturer Data
Manufacturer Info Block A23
77
Hex

System Data
Manufacturer Data
Manufacturer Info Block A24
7a
Hex

System Data
Manufacturer Data
Manufacturer Info Block A25
78
Hex

System Data
Manufacturer Data
Manufacturer Info Block A26
79
Hex

System Data
Manufacturer Data
Manufacturer Info Block A27
30
Hex

System Data
Manufacturer Data
Manufacturer Info Block A28
31
Hex

System Data
Manufacturer Data
Manufacturer Info Block A29
32
Hex

System Data
Manufacturer Data
Manufacturer Info Block A30
33
Hex

System Data
Manufacturer Data
Manufacturer Info Block A31
34
Hex

System Data
Manufacturer Data
Manufacturer Info Block A32
35
Hex

System Data
Manufacturer Info B
Manufacturer Info Block B01
1
Hex

System Data
Manufacturer Info B
Manufacturer Info Block B02
23
Hex

System Data
Manufacturer Info B
Manufacturer Info Block B03
45
Hex

System Data
Manufacturer Info B
Manufacturer Info Block B04
67
Hex

System Data
Integrity
Static DF Signature
0
hex

System Data
Integrity
Static Chem DF Signature
6c98
hex

System Data
Integrity
All DF Signature
0
hex

SBS Configuration
Data
Remaining AH Cap. Alarm
400
mAh

SBS Configuration
Data
Remaining WH Cap. Alarm
432
cWh

SBS Configuration
Data
Remaining Time Alarm
10
min

SBS Configuration
Data
Initial Battery Mode
81
hex

SBS Configuration
Data
Specification Information
31
hex

SBS Configuration
Data
Manufacture Date
2018/11/26
date

SBS Configuration
Data
Serial Number
1
hex

SBS Configuration
Data
Manufacturer Name
BAK

SBS Configuration
Data
Device Name
bq4050

SBS Configuration
Data
Device Chemistry
LION

LED Support
LED Config
LED Flash Period
512
488us

LED Support
LED Config
LED Blink Period
512
488us

LED Support
LED Config
LED Delay
100
488us

LED Support
LED Config
LED Hold Time
5
s

LED Support
LED Config
CHG Flash Alarm
35
%

LED Support
LED Config
CHG Thresh 1
0
%

LED Support
LED Config
CHG Thresh 2
35
%

LED Support
LED Config
CHG Thresh 3
60
%

LED Support
LED Config
CHG Thresh 4
85
%

LED Support
LED Config
CHG Thresh 5
100
%

LED Support
LED Config
DSG Flash Alarm
15
%

LED Support
LED Config
DSG Thresh 1
0
%

LED Support
LED Config
DSG Thresh 2
35
%

LED Support
LED Config
DSG Thresh 3
60
%

LED Support
LED Config
DSG Thresh 4
85
%

LED Support
LED Config
DSG Thresh 5
100
%

Black Box
Safety Status
1st Status Status A
0
hex

Black Box
Safety Status
1st Status Status B
0
hex

Black Box
Safety Status
1st Safety Status C
0
hex

Black Box
Safety Status
1st Safety Status D
0
hex

Black Box
Safety Status
1st Time to Next Event
0
s

Black Box
Safety Status
2nd Status Status A
0
hex

Black Box
Safety Status
2nd Status Status B
0
hex

Black Box
Safety Status
2nd Safety Status C
0
hex

Black Box
Safety Status
2nd Safety Status D
0
hex

Black Box
Safety Status
2nd Time to Next Event
0
s

Black Box
Safety Status
3rd Status Status A
0
hex

Black Box
Safety Status
3rd Status Status B
0
hex

Black Box
Safety Status
3rd Safety Status C
0
hex

Black Box
Safety Status
3rd Safety Status D
0
hex

Black Box
Safety Status
3rd Time to Next Event
0
s

Black Box
PF Status
1st PF Status A
0
hex

Black Box
PF Status
1st PF Status B
0
hex

Black Box
PF Status
1st PF Status C
0
hex

Black Box
PF Status
1st PF Status D
0
hex

Black Box
PF Status
1st Time to Next Event
0
s

Black Box
PF Status
2nd PF Status A
0
hex

Black Box
PF Status
2nd PF Status B
0
hex

Black Box
PF Status
2nd PF Status C
0
hex

Black Box
PF Status
2nd PF Status D
0
hex

Black Box
PF Status
2nd Time to Next Event
0
s

Black Box
PF Status
3rd PF Status A
0
hex

Black Box
PF Status
3rd PF Status B
0
hex

Black Box
PF Status
3rd PF Status C
0
hex

Black Box
PF Status
3rd PF Status D
0
hex

Black Box
PF Status
3rd Time to Next Event
0
s

Lifetimes
Voltage
Cell 1 Max Voltage
5316
mV

Lifetimes
Voltage
Cell 2 Max Voltage
5332
mV

Lifetimes
Voltage
Cell 3 Max Voltage
5321
mV

Lifetimes
Voltage
Cell 4 Max Voltage
5324
mV

Lifetimes
Voltage
Cell 1 Min Voltage
0
mV

Lifetimes
Voltage
Cell 2 Min Voltage
3089
mV

Lifetimes
Voltage
Cell 3 Min Voltage
3115
mV

Lifetimes
Voltage
Cell 4 Min Voltage
3106
mV

Lifetimes
Voltage
Max Delta Cell Voltage
3993
mV

Lifetimes
Current
Max Charge Current
3917
mA

Lifetimes
Current
Max Discharge Current
-17614
mA

Lifetimes
Current
Max Avg Dsg Current
-8372
mA

Lifetimes
Current
Max Avg Dsg Power
-11218
cW

Lifetimes
Temperature
Max Temp Cell
31
°C

Lifetimes
Temperature
Min Temp Cell
17
°C

Lifetimes
Temperature
Max Delta Cell Temp
73
°C

Lifetimes
Temperature
Max Temp Int Sensor
52
°C

Lifetimes
Temperature
Min Temp Int Sensor
16
°C

Lifetimes
Temperature
Max Temp Fet
0
°C

Lifetimes
Safety Events
No Of COV Events
1
events

Lifetimes
Safety Events
Last COV Event
1
cycles

Lifetimes
Safety Events
No Of CUV Events
0
events

Lifetimes
Safety Events
Last CUV Event
0
cycles

Lifetimes
Safety Events
No Of OCD1 Events
0
events

Lifetimes
Safety Events
Last OCD1 Event
0
cycles

Lifetimes
Safety Events
No Of OCD2 Events
0
events

Lifetimes
Safety Events
Last OCD2 Event
0
cycles

Lifetimes
Safety Events
No Of OCC1 Events
0
events

Lifetimes
Safety Events
Last OCC1 Event
0
cycles

Lifetimes
Safety Events
No Of OCC2 Events
0
events

Lifetimes
Safety Events
Last OCC2 Event
0
cycles

Lifetimes
Safety Events
No Of AOLD Events
0
events

Lifetimes
Safety Events
Last AOLD Event
0
cycles

Lifetimes
Safety Events
No Of ASCD Events
0
events

Lifetimes
Safety Events
Last ASCD Event
0
cycles

Lifetimes
Safety Events
No Of ASCC Events
0
events

Lifetimes
Safety Events
Last ASCC Event
0
cycles

Lifetimes
Safety Events
No Of OTC Events
0
events

Lifetimes
Safety Events
Last OTC Event
0
cycles

Lifetimes
Safety Events
No Of OTD Events
0
events

Lifetimes
Safety Events
Last OTD Event
0
cycles

Lifetimes
Safety Events
No Of OTF Events
0
events

Lifetimes
Safety Events
Last OTF Event
0
cycles

Lifetimes
Charging Events
No Valid Charge Term
1
events

Lifetimes
Charging Events
Last Valid Charge Term
0
cycles

Lifetimes
Power Events
No Of Shutdowns
0
events

Lifetimes
Cell Balancing
Cb Time Cell 1
0
h

Lifetimes
Cell Balancing
Cb Time Cell 2
0
h

Lifetimes
Cell Balancing
Cb Time Cell 3
0
h

Lifetimes
Cell Balancing
Cb Time Cell 4
0
h

Lifetimes
Time
Total Fw Runtime
170
h

Lifetimes
Time
Time Spent In UT
0
h

Lifetimes
Time
Time Spent In LT
0
h

Lifetimes
Time
Time Spent In STL
132
h

Lifetimes
Time
Time Spent In RT
22
h

Lifetimes
Time
Time Spent In STH
8
h

Lifetimes
Time
Time Spent In HT
0
h

Lifetimes
Time
Time Spent In OT
0
h

,

Gary Liu4:

客户返回了一个通讯截图和gg文件,从通讯截图来看,3.9V显示22%。gg文件我不知道怎么上传附件, 请查看上一个回复我粘贴过来的信息。

如果是复位按照gg文件里的voltage DOD表更新,应该是在70%到80%之间才对。因为是三元锂电池,如果真的是复位了,根据电压更新应该不太可能有这么大的误差吧?

是否还有其他可能性?烦请帮忙解答一下,谢谢。

,

Star Xu:

您好,reset 以后,会强制soc到7%当电压达到EDV2, SOC到3%当电压达到EDV1, SOC 0%当电压达到EDV0

,

Gary Liu4:

客户说只是充满,没有复位操作。那这样还有什么可能性吗?请帮忙看下,谢谢。

,

Star Xu:

您好,建议您将电池充电并且log数据确认问题。

,

Gary Liu4:

6320.Test.txt

,

Gary Liu4:

我们的产品上4个led是由bq4050控制的,现在只亮两个。然后上一个回复里的txt是客户log的数据,可以看到SOC为55%但是cell电压为4078mV。

我们了解到客户在使用过程中可能不会充满和放空,这样的话我们怀疑这个SOC误差是否是因为没有满充满放造成?

另外现在客户的这种情况,是否能通过某种途径(除了复位以外)来让电池通过gg file里的DOD电压表更新一下SOC? 

请帮忙解答一下,谢谢。

,

Star Xu:

您好,如果怀疑SOC误差是否是因为没有满充满放造成,建议您实际验证一下。
您可以看一下参数的DOD表,Voltage 50% DOD的电压对应的多少。如果误差很大,可能和CEDV Profile 1的参数有关。

赞(0)
未经允许不得转载:TI中文支持网 » BQ4050 三元锂电芯电压达到3.9V但是SOC为0%