cc1120怎么把前导码长度改成200个字节,smartrf默认最多30个字节,有什么办法吗cc1120怎么把前导码长度改成200个字节,smartrf默认最多30个字节,有什么办法吗

cc1120怎么把前导码长度改成200个字节,smartrf默认最多30个字节,有什么办法吗

Kevin Qiu1:

默认是30,看下手册中的说明:www.ti.com.cn/…/swru295e.pdf

Kevin Qiu1:

回复 Kevin Qiu1:

The modulator will first send the programmed number of preamble bytes configured through thePREAMBLE_CFG1.NUM_PREAMBLE register field. If data is available in theTX FIFO, the modulator will send the sync word (programmed through SYNC_CFG0.SYNC_MODE andSYNC3/2/1/0) followed by the payload in the TX FIFO. If CRC is enabled (PKT_CFG1.CRC_CFG =1 or 10b), the checksum is calculated over all the data pulled from the TX FIFO, and the result issent as two extra bytes following the payload data.