do i need to load the xwr22xx_metalmage.bin every time when i use the lua script to capture data after opening the mmwave studio ? Because i find that loadindg the xwr22xx_metalmage.bin file costs a lot of time , and in the script it load the four devices one by one. can i load this file together rather than master ,slave1,slave2,slave3.
Chris Meng:
你好,
对于MIMO的数据采集,如果配置不变的话,是可以调用一次配置LUA,然后多次调用数据采集的LUA的。
user5159635:
回复 Chris Meng:
i mean if i can load the .binonly one time.Every time iboot the board and connect with the pc, i need to load this .bin file , and it will take a long time. Soi want to skip this download. But when i have a try changing the command in theconfiguration script ,i fail to connect the rf power. Do we must download this file everytime ? Do ihave another way to download this .bin file to reduce some time it takes.
Chris Meng:
回复 user5159635:
你好,
你说的bin文件是AWR2243的firmware,对么?对于AWR2243的配置,有些是可以动态修改的,那就不需要重新加载firmware。但有些参数需要芯片断电后才能设置更改,那就需要重新下载firmware了。
对于哪些参数可以动态配置,哪些修改必须重启芯片,请下载DFP 软件包,参考里面的文档mmWave-Radar-Interface-Control.pdf。
user5159635:
回复 Chris Meng:
我说的文件是在进行RF POWER连接之前需要下载的 xwr22xx_metalmage.bin 。每次通电之后要对四个芯片分别下载一次时间有点久。
Chris Meng:
回复 user5159635:
你好,
你说的就是我提到的firmware。
user5159635:
回复 Chris Meng:
那能不能一次加载四个firmware而不是一个芯片一个芯片的加载
user5159635:
回复 Chris Meng:
那能不能一次加载四个firmware而不是一个芯片一个芯片的加载
user5159635:
回复 Chris Meng:
好的。谢谢回复