你们好,因为我想用Observer设备监听另外2个主从设备建立连接后的数据通道的数据,所以我想问一下,CC2640R2F主从设备在建立连接后,
1. 有提供获取数据信道MAP和当前信道值的接口吗
2. 如果有,那么设置当前跳频通道的频率的寄存器在CC13x0, CC26x0 SimpleLink™ Wireless MCU手册中可以找到吗
Viki Shi:
可以参考一下connection monitor这个例程,路径:C:\ti\simplelink_cc2640r2_sdk_4_10_00_10\examples\rtos\CC2640R2_LAUNCHXL\blestack\connection_monitor
The Connection Monitor (CM) project utilizes the monitor role from the TI Micro BLE Stack (uBLE-Stack) to collect connection data from external BLE connections without having to formally participate in a BLE connection. The monitor role is not an official BLE Specification defined role. It is designed to follow an active BLE connection given the following parameters:
Access address
Connection Interval
Hop Increment Value
Channel Map
Master Sleep Clock Accuracy (mSCA)
user5975578:
回复 Viki Shi:
谢谢,正在尝试解决,已经在SDK中找到了例程,但是我现在手上的板子只有2块,一个是CC2640R2F,可以正常使用,用作CM;
另一个是CC2652R1板子,直接烧录host_test_app.hex程序后,用BTool工具打开时,出现 GAP Device Initialization Timeout错误;在尝试CCS中导入 host_test_app工程,在Debug模式下,用BTool工具打开,也出现同样的问题,不知道是什么原因导致的?
Viki Shi:
回复 user5975578:
烧录host_test_app.hex后需要复位一下,再连接Btool
user5975578:
回复 Viki Shi:
复位后,还是一样的现象,而且我用uniflash再次烧写的时候,点了 Verify Image后,cc2652r1板子串口不能在设备管理器出现了,PC已经识别不到板子了
user5975578:
回复 user5975578:
现在我手上2块CC2652R1的板子都不能被PC识别到,感觉问题严重了,是不是板子被锁住了,还是XDS110调试接口出现问题了?
Viki Shi:
回复 user5975578:
请问你的板子是什么版本的?
user5975578:
回复 Viki Shi:
HW Rev : B
FW:SDK 2.401851
Viki Shi:
回复 user5975578:
连接smartrf flash programmer可以被识别吗?如果可以,mass erase一下
user5975578:
回复 Viki Shi:
smartrf flash programmer识别不到板子,现在是PC上的设备管理器都识别不到,我看之前有个人也遇到了同样的问题,你好像也回复他了