TI中文支持网
TI专业的中文技术问题搜集分享网站

GPCCHEM上传电池充放电文件时报错,请帮忙看一下

上传后ti邮件回复

the following errors were reported by the calculation engine:
Error: Wrong data format, make sure file has coma or tab separated values. Name: roomtemp_rel_dis_rel.csv

文件名应该没问题,上面提到的格式是什么意思??

answer:

可能是上传的文件的格式不对,将log数据导入excel时,需要选择coma,将数据进行分隔,导入数据时使用excel 的data菜单,然后选择 from text

xukai kai:

回复 answer:

你好,我把数据调整了一下,现在报的错误是,请帮忙看一下,上传了新的附件

The following errors were reported by the calculation engine:Accuracy Error: Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule 

xukai kai:

回复 answer:

你好我调整数据后上传,现在报的错误是

The following errors were reported by the calculation engine:Accuracy Error: Deviation is so high that it is most likely due to anomaly in the data. Please check that data files have recomended format, units and test schedule 

请帮忙看一下,难道是因为我放电时电压下降多,软件认为不对了??附件是新的数据文件

Richard Tang:

回复 xukai kai:

从你的数据来看,感觉充放电的电流明显不对啊,请按照如下的步骤测试数据:

1. 设置数据采集间隔为4S,采集时间,电流,电压和温度.

2. 把电芯充饱至电流小于1C/100。

3. 静置两个小时.

4.  用0.1C的电流把电芯放电至2.9V左右。

5. 静置两到五个小时。

6. 把数据导入mathcad工具进行计算。

7.  采用多个电芯测试得到多组数据,找出最符合所有电芯的ID

xukai kai:

回复 Richard Tang:

你好,我用的是5300mah 3.7伏电压四节并联的锂电池,容量应该是20000mah。充电到小于1/100c,就是小于200ma应该满足了,是最终充电电流太小了吗?

0.1c放电,2000ma左右放电应该也没错啊?放到低于 2.5伏太低了吗?主要我不知道放电终止电压,我看gpcchem文档画的放到电压低于2.5伏了,这样不对吗?谢谢

xukai kai:

回复 Richard Tang:

好的,我用单电芯再测下

xukai kai:

回复 Richard Tang:

电池如果是3.7伏的,冲饱电压应该是比3.7伏稍多一点?需要先恒流再恒压,充到差不多了再涓流?例如3.9伏,4.3伏太高了吗?

Star Xu:

回复 xukai kai:

建议您看一下电池规格书,3.7V是标称,充饱是4.2V还是4.3V

xukai kai:

回复 Star Xu:

你好,Boston  5300电芯,充电限值为4.2伏,我开始用 4伏电压充,电流大约1.5a,到充电电流小于1a,我把电压升到4.2伏继续充直到小于0.01c,这样可以吗?

赞(0)
未经允许不得转载:TI中文支持网 » GPCCHEM上传电池充放电文件时报错,请帮忙看一下
分享到: 更多 (0)