Part Number:LP-MSPM0G3507Other Parts Discussed in Thread:MSPM0G3507
I want to flash a project to mspm0g3507,but the CCS tell me an error
Texas Instruments XDS110 USB Debug Probe/CORTEX_M0P Error connecting to the target: Connection to MSPM0 core failed. Possible root causes: 1) Debug access within NONMAIN was disabled or enabled with password. 2) Peripheral mis-configuration (e.g improper watchdog or clock). To see a more detailed diagnostic of the issue, please press the 'Read boot diagnostic' button.
I am desired to kown how to deal with the problem.
Vivian Gao:
感谢您对TI产品的关注! 关于你的咨询,我们正在确认你的问题,稍后回复您。
,
Daniel:
您好
PA18是BSL调用引脚,如果PA18在复位/通电期间为高电平,MSPM0将进入BSL(引导加载程序)模式。
2.
Cz Ushio 说:Debug access within NONMAIN was disabled or enabled with password.
您的应用程序代码或CCS项目是否试图修改非主要区域?
Cz Ushio 说:2) Peripheral mis-configuration (e.g improper watchdog or clock). To see a more detailed diagnostic of the issue, please press the 'Read boot diagnostic' button.
尝试进入BSL模式,然后通过SWD连接MSPM0并解锁MSPM0。
此外,您可以将启动诊断代码反馈给我们。
以下是其他解锁注释:
有关 CCS 解锁 MSPM0的信息、请参阅 www.ti.com/…/slaaed1 7.1.4通过 CCS 解锁
如果常见步骤不可行、请尝试对 MSPM0重新供电、并使 PA18保持为高电平、MSPM0将进入 BSL 模式。
然后尝试在 CCS 目标配置中连接 MSPM0 DPA 端口。 (显示所有内核–连接 DAP)。
硬件检查、检查电源(客户定义、3.3V)、检查 Vcore 电压(1.35V)。检查 XDS110连接、该连接位于 PC 的设备管理器列表中。可选的固件、可确认 M0是否在应用中运行。这将帮助您确认是否成功进入 BSL 模式。
方法:在 CCS 中运行恢复出厂设置自动脚本–目标配置方法:在 CCS 中连接 DAP、手动运行恢复出厂设置脚本–目标配置方法:进入 BSL 模式、连接 DAP、然后在 CCS 中手动运行恢复出厂设置脚本–目标配置
以下方法因信号质量问题而有助于降低 MSPM0锁定频率:
缩短 XDS110和 MSPM0之间的调试电缆(SWDIO 和 SWCLK)的长度。在20cm 以内是可以的、10cm 更好。
降低调试器 SWD 速度、双击.ccxml 文件、然后在 TI XDS110 USB 调试探针中更改速度分别对 MAIN 区域和非 MAIN 区域进行编程